Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
Biomimetics (Basel) ; 9(4)2024 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-38667205

RESUMEN

Solvent evaporation within an adhesive layer is a crucial step during a bonding process. The aim of this current research was to test whether the use of different air temperatures (20 °C, 40 °C, and 60 °C) for solvent evaporation improves the performance of four adhesive systems to dentin. Sixty non-carious human molar teeth were randomly prepared for micro-tensile bond strength (µTBS) tests. Four different adhesive systems, Prime&Bond Universal (PBU), OptiBond Universal (OBU), OptiBond FL (OBFL), and Clearfil SE (CSE), were applied following the manufacturer's instructions. Three groups based on the air-drying temperature were used: solvent evaporation was performed with either of warm (40 °C), (60 °C), and cold air as control group (20 °C) for 10 s at a distance of 5 cm. In all bonded surfaces, three resin composite (Reflectys, Itena Clinical, Paris, France) layers of 2 mm thickness were built up. The resin-dentin samples were kept in distilled water at 37 °C for 24 h and 6 months, respectively, before µTBS testing. Failure analysis, scanning electron microscopy of resin-dentin bonded interface, and solvent evaporation rate were tested as secondary variables. All analyses were conducted using a significance level of α = 0.05. Bond strength (BS) values were similar among all the adhesive systems used (p > 0.05). Also, the aging factor did not affect the BS (p > 0.05). Only the factor of temperature used for solvent evaporation resulted in a statistically significant effect (p < 0.05), with the temperature of 60 °C being the highest value (p < 0.05). A failure mode evaluation revealed mostly adhesive or mixed modes of failures in all the different temperatures of air used for the solvent evaporation of each adhesive system. The thickness of the adhesive layer and the creation of resin tags varied amongst the temperatures evaluated. For all adhesive systems tested, the use of 40 °C or 60 °C air for solvent evaporation led to an increased mass loss. Warmer temperatures for solvent evaporation contributed positively to bonding performance, enhancing both the quality of the adhesive layer and its interaction with the dentin tissue. Optimizing solvent evaporation with warmer air temperatures (40 °C and 60 °C) significantly improved µTBS, offering a practical means to enhance the quality and longevity of adhesive restorations in esthetic dentistry.

2.
Dent J (Basel) ; 12(4)2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38668030

RESUMEN

The aim of this investigation was to conduct a systematic review and meta-analysis to determine the necessity of a white diet during or following a bleaching procedure. This systematic review and meta-analysis followed the PRISMA guidelines meticulously. The research question was: Is a white diet necessary during and/or after a bleaching treatment? In vitro studies or clinical trials reporting the color change in bleached enamel after the use of a free-staining diet were considered for full-text review. For the analyses, a random-effects model was employed. Statistical significance was defined as a p-value < 0.05. A total of 17 documents were eligible for qualitative analysis: 5 clinical trials and 12 in vitro studies. Only data from the clinical trials were included in the meta-analysis. For at-home bleaching, differences in the color among the subjects were not statistically significant during the first (p = 0.64), second (p = 0.26) or third (p = 0.43) weeks of treatment. Also, the color difference one month after finishing the bleaching treatment were not statistically significant (p = 0.27). The color difference one month after finishing an in-office treatment showed that the restrictions on diet did not significantly improve the bleaching outcomes (p = 0.90). According to the findings of this review, dietary restrictions are not necessary during or after bleaching procedures.

3.
J Funct Biomater ; 15(3)2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38535263

RESUMEN

This study aimed to evaluate the antimicrobial properties, cell viability, and matrix metalloproteinase (MMP) inhibition capacity of several endodontic materials aimed at vital pulp therapy: Pro Root MTA®, EndoSequence®, Biodentine®, MTA Angelus®, TheraCal LC®, and BioC Repair®. The materials were prepared according to the manufacturer's instructions. Antimicrobial tests were conducted using a microcosm biofilm model, cell viability was assessed using murine fibroblasts (L929), and MMP activity was analyzed through electrophoresis. The results showed that BioC Repair®, Biodentine®, and EndoSequence® exhibited similar antimicrobial properties, while MTA Angelus® and ProRoot MTA® had inferior results but were comparable to each other. In terms of cell viability, no significant differences were observed among the materials. EndoSequence® demonstrated the highest MMP inhibition capacity. In conclusion, BioC Repair®, Biodentine®, EndoSequence®, and TheraCal® showed better antimicrobial properties among the tested materials. The materials did not exhibit significant differences in terms of cytotoxicity. However, EndoSequence® displayed superior MMP inhibition capacity.

4.
J Appl Oral Sci ; 32: e20230219, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38232277

RESUMEN

OBJECTIVE: In this study, a comparative evaluation of the physicochemical properties of Cention N and other direct restorative materials was performed. Three restorative materials-a resin-modified glass ionomer (Fuji II LC), an alkasite-based resinous material (Cention N), and a resin composite (Tetric N Ceram)-were characterized in terms of degree of conversion, Knoop hardness number (KHN) ratio, flexural strength, elastic modulus, water sorption, water solubility, microshear bond strength to dentin, immediate microleakage, and radiopacity. METHODOLOGY: The microshear bond strength to dentin and microleakage of Cention N were evaluated with and without the application of an adhesive system (Tetric N Bond Universal). A one-way ANOVA test was used to analyze the data in terms of degree of conversion, KHN ratio, water sorption, water solubility, microshear bond strength to dentin, and radiopacity. A two-way ANOVA test (carried out considering the material type and ethanol aging as factors) was used to analyze the data in terms of flexural strength and elastic modulus. The Kruskal-Wallis test was used to statistically analyze the data on microleakage. A significance level of α=0.05 was used for all tests. RESULTS: Fuji II LC was found to have the highest degree of conversion, water sorption, and microleakage, as well as the lowest flexural strength. Cention N had the highest solubility; when used with an adhesive system, it achieved bond strength and microleakage similar to those of the Tetric N Ceram composite. Tetric N Ceram had the highest degree of conversion, KHN ratio, and radiopacity. Conclusion: The properties of Cention N validate its efficacy as an alternative direct restorative material when used in conjunction with an adhesive system.


Asunto(s)
Resinas Compuestas , Restauración Dental Permanente , Resinas Compuestas/química , Materiales Dentales/química , Cementos de Ionómero Vítreo/química , Agua , Ensayo de Materiales
5.
J. appl. oral sci ; 32: e20230219, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1528890

RESUMEN

Abstract Objective: In this study, a comparative evaluation of the physicochemical properties of Cention N and other direct restorative materials was performed. Three restorative materials—a resin-modified glass ionomer (Fuji II LC), an alkasite-based resinous material (Cention N), and a resin composite (Tetric N Ceram)—were characterized in terms of degree of conversion, Knoop hardness number (KHN) ratio, flexural strength, elastic modulus, water sorption, water solubility, microshear bond strength to dentin, immediate microleakage, and radiopacity. Methodology: The microshear bond strength to dentin and microleakage of Cention N were evaluated with and without the application of an adhesive system (Tetric N Bond Universal). A one-way ANOVA test was used to analyze the data in terms of degree of conversion, KHN ratio, water sorption, water solubility, microshear bond strength to dentin, and radiopacity. A two-way ANOVA test (carried out considering the material type and ethanol aging as factors) was used to analyze the data in terms of flexural strength and elastic modulus. The Kruskal-Wallis test was used to statistically analyze the data on microleakage. A significance level of α=0.05 was used for all tests. Results: Fuji II LC was found to have the highest degree of conversion, water sorption, and microleakage, as well as the lowest flexural strength. Cention N had the highest solubility; when used with an adhesive system, it achieved bond strength and microleakage similar to those of the Tetric N Ceram composite. Tetric N Ceram had the highest degree of conversion, KHN ratio, and radiopacity. Conclusion: The properties of Cention N validate its efficacy as an alternative direct restorative material when used in conjunction with an adhesive system.

6.
J Funct Biomater ; 14(10)2023 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-37888187

RESUMEN

The goal of this article was to assess the effect of modified triple-layer application (MTLA) in conjunction with the active bonding technique on the bond strength of four adhesive systems to dentinal substrate. The adhesives tested were Prime&Bond Universal (PBU), OptiBond Universal (OBU), OptiBond FL (OBFL), and Clearfil SE (CSE). The adhesives were applied according to the following strategies: single active application (A) and triple adhesive layer application including Active-Passive-Passive (APP); AAP; and AAA. The micro-tensile bond strength test was evaluated following 24 h or 6 months of storage. The composite-dentin interface morphology was investigated using scanning electron microscopy. The data were statistically analyzed with a significance level of α = 0.05. At 24 h of aging, all of the factors tested were not significant (p > 0.05) for CSE. For OBFL, OBU, and PBU, statistically higher values were observed for the A technique (p < 0.05). Plus, there were no significant variances between the APP, AAP, and AAA techniques (p > 0.05) for OBFL and PBU. However, for OBU, there were no significant differences between the A and AAA techniques (p > 0.05). After 6 months of aging, the A technique showed statistically higher values when compared to the other techniques (p < 0.01), except for OBFL, where the A and AAA techniques showed promising outcomes. When comparing the bond strength values of 24 h and 6 months, only for PBU, all of the techniques used resulted in bond strength stability over time (p > 0.05). Thicker adhesive layers were observed when MTLA was applied. Only the OBFL adhesive showed the formation of resin tags in all of the modalities tested. The bonding performances of the different application techniques used were material-dependent.

7.
Polymers (Basel) ; 15(19)2023 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-37835974

RESUMEN

One of the major goals of adhesive dentistry is to improve the interaction of the already-existing adhesives with different substrates by using different application techniques. Thus, the objective of the present in vitro study was to assess the bond performance of four adhesive systems, Prime&Bond Universal (PBU), Clearfil SE Bond (CSE), OptiBond Universal (OBU), and OptiBond FL (OBFL), to dentin using various application modes: passive application (PA), active application (AA), Compo-Vibes modified application (CVM), and Compo-Vibes application (CV). Eighty extracted human molars were allocated into four groups based on the application modalities tested. The micro-tensile bond strength as well as fracture mode were tested in accordance with ISO/TS 11.405 after 24 h and 6 months of aging. Adhesive contact angle (CA) and scanning electron microscope analysis were also performed (n = 3). Statistical tests were performed with α = 0.05. After 24 h, a significant difference with a higher bond strength value was found for PBU in the AA modality and for CSE in the CVM modality (p < 0.05). However, no significant difference was shown between the techniques used among the other adhesives (OBFL and OBU). Moreover, at 24 h, only the PA demonstrated significant differences between the tested materials (p < 0.05). After 6 months, CSE, PBU, and OBU demonstrated significant differences between the techniques (p < 0.05), with a higher bond strength for CSE in AA and CVM modalities, for PBU in AA modality, and for OBU in AA and PA modalities. No significant differences were found between the techniques used among the OBFL (p > 0.05). In addition, only the CVM technique demonstrated significant differences between the tested materials after 6 months. CV and CVM showed a decreased value after aging for CSE and PBU, respectively. However, all the modalities decreased for OBU and OBFL after aging. All the adhesives showed marked resin infiltration into dentinal tubules in AA among all the modalities tested. Both universal adhesive systems (OBU and PBU) demonstrated statistically lower CA when compared to the other systems (CSE and OBFL) (p < 0.05) when applied in the PA mode. Concerning the AA mode, only CSE and OBFL were tested. The AA demonstrated lower CA values compared to the same adhesives in PA (p < 0.05). It could be concluded that the bond strength could be influenced by both materials and application techniques. It seems that the AA technique could be recommended as a gold standard for the application of an adhesive system to dentin. Plus, the CV and CVM modalities after 6 months of aging were considered stable for PBU and CSE, respectively. Consequently, the performance of these adhesive systems might vary when applied to other modalities. Future studies are needed to test this hypothesis.

8.
J Prosthodont ; 2023 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-37653684

RESUMEN

PURPOSE: This systematic review and meta-analysis aimed to evaluate the difference in the color stability of light-cured and dual-cured resin cements. MATERIALS AND METHODS: Two separate reviewers used the PubMed, Scopus, Web of Science, Embase, and Scielo databases to execute the systematic review. For the analysis, studies that evaluated the color stability of dual-cured and light-cured resin cements over time were used. The random effects model was used in the meta-analysis. Analyses of subgroups were carried out based on the aging technique. The methodological quality of each in vitro study was evaluated in accordance with the parameters of a prior systematic review. RESULTS: From all databases, a total of 2223 articles were retrieved. Following the screening of titles and abstracts, 44 studies were selected for full text review, and a total of 27 articles were used for the qualitative analysis. Finally, 23 articles remained for the qualitative analysis. The majority of studies were labeled as having a medium risk of bias. The global analysis showed that the dual-cure resin cements had considerably greater differences in the color change (p = 0.006). A high heterogeneity index (86%) was found in the analysis. CONCLUSIONS: The best available in vitro evidence suggests that dual-polymerizing cement has higher color variation than light-polymerized materials. To reduce the likelihood of color change after the luting of thin ceramic restorations, clinicians should employ light-polymerizable resin cements.

9.
J Esthet Restor Dent ; 35(8): 1218-1238, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37395344

RESUMEN

INTRODUCTION: In a suitable condition, it is important to perform any dental restorative procedure using an operatory field isolated. Then, the aim of this study was to compare the bond strength of composite restorations to dentin affected by any contamination agent through a systematic review. METHODS: This systematic review was performed following the PRISMA 2020 guidelines. The literature search was conducted until September 2022 by scanning the following databases: Embase, PubMed, Scielo, Scopus, and Web of Science. Manuscripts evaluated the bond strength of resin-based materials to permanent human dentin contaminated with blood or saliva were selected for full-text review. The risk of bias was assessed by the RoBDEMAT tool. RESULTS: A total of 3750 papers resulted from the search from all databases. After the full-text reading, a total of 62 articles remained for the qualitative analysis. The contamination agents used were blood, saliva, and hemostatic agents. A great variety of protocols were used to contaminate the dentin surface, and the contamination process occurred in several steps of the bonding process, including before and after the etching process, after the primer application and after the adhesive application. Also, several decontamination procedures were tested, including reapplication of the etching material, rinsing with water, chlorhexidine or sodium hypochlorite and reapplication of the adhesive system. CONCLUSION: Any contamination with blood or saliva impaired the bond strength of resin-based materials to dentin. Decontamination procedures including water-spray and reapplication of the bonding system could revert the impairment produced by the saliva or blood contamination. The use of hemostatic agents as a method of blood decontamination is not recommended. CLINICAL SIGNIFICANCE: Clinicians should avoid contamination during a bonding procedure, otherwise, a reduction in the bond quality is expected.


Asunto(s)
Recubrimiento Dental Adhesivo , Hemostáticos , Humanos , Cementos Dentales/química , Recubrimientos Dentinarios/química , Cementos de Resina/química , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Propiedades de Superficie , Descontaminación , Hemostáticos/química , Dentina , Agua/química , Ensayo de Materiales
10.
J Funct Biomater ; 14(5)2023 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-37233396

RESUMEN

Any excess solvent from dental adhesive systems must be eliminated prior to material photopolymerization. For this purpose, numerous approaches have been proposed, including the use of a warm air stream. This study aimed to investigate the effect of different temperatures of warm air blowing used for solvent evaporation on the bond strength of resin-based materials to dental and nondental substrates. Two different reviewers screened the literature in diverse electronic databases. In vitro studies recording the effect of warm air blowing to evaporate solvents of adhesive systems on the bond strength of resin-based materials to direct and indirect substrates were included. A total of 6626 articles were retrieved from all databases. From this, 28 articles were included in the qualitative analysis, and 27 remained for the quantitative analysis. The results of the meta-analysis for etch-and-rinse adhesives revealed that the use of warm air for solvent evaporation was statistically significantly higher (p = 0.005). For self-etch adhesives and silane-based materials, this effect was observed too (p < 0.001). The use of a warm air stream for solvent evaporation enhanced the bonding performance of alcohol-/water-based adhesive systems for dentin. This effect seems to be similar when a silane coupling agent is submitted to a heat treatment before the cementation of a glass-based ceramic.

11.
Biofouling ; 39(1): 110-120, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36946247

RESUMEN

This study aimed to evaluate the antimicrobial activity and physicochemical properties of a novel dual-cure endodontic sealer containing copaiba oil. The copaiba oil was obtained and characterized by gas chromatography (GC), and the minimum inhibitory concentration (MIC) was performed. The experimental sealers were formulated with copaiba oil concentrations of 0, 0.5, 1, and 2%, and the RealSeal™ (Sybron endo, Orange, USA) and AH Plus (Dentsply De Trey Gmbh, Konstanz, Germany) were used as the commercial references. The antimicrobial activity of the sealers was evaluated by the direct contact test for 1h and 24h. To evaluate the physicochemical properties of the sealers, the degree of conversion, setting time, film thickness, dimensional stability, and radiopacity tests were performed. The data were statistically analyzed by one-way ANOVA and Tukey's test (α = 0.05). Concerning the results, the sealers containing copaiba oil showed antimicrobial activity without harming the physicochemical properties.


Asunto(s)
Aceites Volátiles , Materiales de Obturación del Conducto Radicular , Materiales de Obturación del Conducto Radicular/farmacología , Materiales de Obturación del Conducto Radicular/química , Enterococcus faecalis , Ensayo de Materiales , Biopelículas , Antibacterianos/farmacología , Aceites Volátiles/farmacología
12.
Rev. cuba. estomatol ; 60(1)mar. 2023.
Artículo en Español | LILACS, CUMED | ID: biblio-1521909

RESUMEN

Introducción: La fijación de las restauraciones indirectas es uno de los pasos más importantes, para conseguir una adecuada retención y sellado de la interfase entre el material restaurador y el diente. Objetivo: Evaluar la resistencia de unión al cizallamiento de diferentes agentes de fijación a dos aleaciones metálicas utilizadas en odontología. Métodos: Estudio experimental in vitro. Cien especímenes de aleaciones de metales base, 50 de níquel-cromo y 50 de níquel-cromo-titanio fueron preparados y divididos de manera aleatoria en 5 grupos. Esta división se realizó acorde con el agente de fijación utilizado: sistema autograbante de dos pasos (Clearfil SE Bond; CSB), sistema adhesivo universal (Single Bond Universal; SBU), cemento resinoso autoadhesivo (Maxcem Elite; ME), ionómero de vidrio (IV) y fosfato de zinc (ZnPO). Posteriormente a la aplicación de cada agente de fijación, los especímenes tratados fueron almacenados en agua destilada por 24 h a 37 ºC y sometidos a un ensayo de resistencia de unión al cizallamiento. Resultados: La resistencia de unión al cizallamiento fue influenciada significativamente por el tipo de agente de fijación (p = 0,002) y el tipo de aleación utilizada (p < 0,001). La resistencia de unión al cizallamiento fue mayor, al utilizar el sistema Clearfil SE Bond, seguida de Single Bond Universal; las diferencias entre Maxcem Elite y el Fosfato de zinc no fueron significativas. Finalmente, el IV no mostró adhesión a ninguna de las aleaciones metálicas utilizadas. Conclusiones: El uso de Clearfil SE Bond aumentó la resistencia de unión de los cementos resinosos a las aleaciones metálicas(AU)


Introduction: The bonding of indirect restorations is one of the most important steps, in order to achieve adequate retention and sealing of the interface between the restorative material and the tooth. Objective: To evaluate the shear bond strength of different bonding agents to two metal alloys used in dentistry. Methods: In vitro experimental study. One hundred specimens of base metal alloys, 50 nickel-chromium and 50 nickel-chromium-titanium were prepared and randomly divided into 5 groups. This division was made according to the bonding agent used: two-step self-etching system (Clearfil SE Bond; CSB), universal adhesive system (Single Bond Universal; SBU), self-adhesive resin cement (Maxcem Elite; ME), glass ionomer (IV) and zinc phosphate (ZnPO). After the application of each bonding agent, the treated specimens were stored in distilled water for 24 hr at 37 ºC and subjected to a shear bond strength test. Results: Shear bond strength was significantly influenced by the type of bonding agent (p = 0.002) and the type of alloy used (p < 0.001). Shear bond strength was highest when using the Clearfil SE Bond system, followed by Single Bond Universal; the differences between Maxcem Elite and Zinc Phosphate were not significant. Finally, IV did not show adhesion to any of the metal alloys used. Conclusions: The use of Clearfil SE Bond increased the bond strength of resinous cements to metallic alloys(AU)


Asunto(s)
Humanos , Recubrimiento Dental Adhesivo/métodos , Cemento Dental
13.
Bioengineering (Basel) ; 10(2)2023 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-36829663

RESUMEN

Nowadays, the ceramic veneer approach can be considered more predictable than direct composite veneer. To date, there is a lack of studies comparing the clinical performance of anterior veneers cemented on vital teeth (VT) and non-vital teeth (NVT). This longitudinal clinical study investigated the performance of ceramic veneers in VT or anterior NVT. A total of 55 patients were evaluated in the study. Two groups were defined based on the vitality status of the teeth (93 teeth-vital and 61 teeth-non-vital). The United States Public Health Service (USPHS) criteria were used to assess the clinical status. The data were evaluated statistically with the Mann-Whitney U test. All restorations were considered acceptable, and only one veneer in VT failed for the criteria of secondary caries. There were no statistically significant differences in any of the criteria evaluated (p ≤ 0.671). The ceramic veneers evaluated showed a satisfactory clinical performance both in VT and NVT.

14.
Bioengineering (Basel) ; 10(2)2023 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-36829708

RESUMEN

Currently, it remains unclear which specific peptides could be appropriate for applications in different fields of dentistry. The aim of this scoping review was to scan the contemporary scientific papers related to the types, uses and applications of peptides in dentistry at the moment. Literature database searches were performed in the following databases: PubMed/MEDLINE, Scopus, Web of Science, Embase, and Scielo. A total of 133 articles involving the use of peptides in dentistry-related applications were included. The studies involved experimental designs in animals, microorganisms, or cells; clinical trials were also identified within this review. Most of the applications of peptides included caries management, implant osseointegration, guided tissue regeneration, vital pulp therapy, antimicrobial activity, enamel remineralization, periodontal therapy, the surface modification of tooth implants, and the modification of other restorative materials such as dental adhesives and denture base resins. The in vitro and in vivo studies included in this review suggested that peptides may have beneficial effects for treating early carious lesions, promoting cell adhesion, enhancing the adhesion strength of dental implants, and in tissue engineering as healthy promotors of the periodontium and antimicrobial agents. The lack of clinical trials should be highlighted, leaving a wide space available for the investigation of peptides in dentistry.

15.
Cells ; 12(1)2023 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-36611983

RESUMEN

Diverse types of dental adhesives exhibit different cytotoxic outcomes on cells in vitro. Currently, no standard adhesive application technique has so far been decisive for clinicians for better durability of resin-dentin bonds of adhesive systems. The purpose of this study was to systematically review the literature to evaluate the bonding performance of adhesive systems to dentin by using different application modalities. The systematic research strategy was conducted by two reviewers among multiple databases: PubMed, Scopus, Web of Science, Embase, and Scielo. In vitro studies reporting the effects of additional steps for the application of adhesive systems on the bond strength to dentin were selected. Meta-analysis was performed using Review Manager Software version 5.3.5 using the random effects model. The methodological quality of each in vitro study was assessed according to the parameters of a previous systematic review. The electronic research through different databases generated a total of 8318 references. After the examination of titles and abstracts, a total of 106 potentially relevant studies accessed the full-text evaluation phase. After full-text examination, 78 publications were included for the qualitative analysis, and 68 studies were included in the meta-analysis. Regarding the etch-and-rinse adhesive systems, the application modalities that improved the overall bond strength were the application of a hydrophobic resin layer (p = 0.005), an extended application time (p < 0.001), an application assisted by an electric current (p < 0.001), a double-layer application (p = 0.05), the agitation technique (p = 0.02), and the active application of the adhesive (p < 0.001). For self-etch adhesive systems, the techniques that improved the overall bond strength were the application of a hydrophobic resin layer (p < 0.001), an extended application time (p = 0.001), an application assisted by an electric current (p < 0.001), a double-layer application (p < 0.001), the agitation technique (p = 0.01), and the active application of the adhesive (p < 0.001). The in vitro evidence suggests that the application of adhesive systems using alternative techniques or additional strategies may be beneficial for improving their bond strength to dentin. The application modalities that favored the overall bond strength to dentin were an extended application time, a double-layer application, an application assisted by an electric current, the active application of the adhesive, and the application of a hydrophobic resin layer. Worth mentioning is that some techniques are intended to increase the degree of the conversion of the materials, and therefore, improvements in the biocompatibility of the materials can be expected.


Asunto(s)
Adhesivos , Dentina , Recubrimientos Dentinarios/química , Ensayo de Materiales , Cementos de Resina/química
16.
J Esthet Restor Dent ; 35(3): 493-500, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36260931

RESUMEN

OBJECTIVE: Problems in the confection of indirect restorations may increase the marginal and internal gap. This study aimed to quantify the marginal and the internal fit of overlays fabricated with three different materials. MATERIALS AND METHODS: Standardized cavities were prepared on endodontically treated human third molars and digital impressions were done using an intraoral camera (Trios 3). Restorations were designed (n = 15) and fabricated with three materials: Hybrid ceramic (Cerasmart; GC Corp, EUROPE), high-strength lithium disilicate (GC Initial® LiSi Press; GC Corp, Tokyo, Japan), and zirconia reinforced Lithium Silicate Glass Ceramic (Vita Suprinity; Vita, Germany). Axial, marginal, pulpal, and gingival gaps were calculated by measuring the distance between the restoration and the tooth at several reference points. Two-Way analysis of variance was used for statistical analysis. The significance level was set at α = 0.05. RESULTS: Mean gap was significantly influenced by the material (p < 0.001), gap localization (p < 0.001), and interaction between the factors (p = 0.002). For all materials, the highest gap was observed at gingival and pulpal surfaces (p ≤ 0.015). LiSi Press achieved the overall lowest values at axial values measurements (p ≤ 0.003). CONCLUSIONS: The performance of a CAD/CAM system relative to marginal adaptation is influenced by the restorative material used. High-strength lithium disilicate seems to be showed the best marginal adaptation. CLINICAL SIGNIFICANCE: Marginal and internal adaptation of CAD/CAM restorations could be influenced by the type of material chosen.


Asunto(s)
Coronas , Diseño de Prótesis Dental , Humanos , Adaptación Marginal Dental , Materiales Dentales , Diseño Asistido por Computadora
17.
J Adv Prosthodont ; 15(6): 315-332, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38205120

RESUMEN

PURPOSE: This study aimed to investigate whether the accuracy of intraoral scanners is influenced by different scanning strategies in an in vitro setting, through a systematic review and meta-analysis. MATERIALS AND METHODS: This review was conducted in accordance with the PRISMA 2020 standard. The following PICOS approach was used: population, tooth impressions; intervention, the use of intraoral scanners with scanning strategies different from the manufacturer's instructions; control, the use of intraoral scanners following the manufacturers' requirements; outcome, accuracy of intraoral scanners; type of studies, in vitro. A comprehensive literature search was conducted across various databases including Embase, SciELO, PubMed, Scopus, and Web of Science. The inclusion criteria were based on in vitro studies that reported the accuracy of digital impressions using intraoral scanners. Analysis was performed using Review Manager software (version 5.3.5; Cochrane Collaboration, Copenhagen, Denmark). Global comparisons were made using a standardized mean difference based on random-effect models, with a significance level of α = 0.05. RESULTS: The meta-analysis included 15 articles. Digital impression accuracy significantly improved under dry conditions (P < 0.001). Moreover, trueness and precision were enhanced when artificial landmarks were used (P ≤ 0.02) and when an S-shaped pattern was followed (P ≤ 0.01). However, the type of light used did not have a significant impact on the accuracy of the digital intraoral scanners (P ≥ 0.16). CONCLUSION: The accuracy of digital intraoral scanners can be enhanced by employing scanning processes using artificial landmarks and digital impressions under dry conditions.

18.
J Evid Based Dent Pract ; 22(4): 101776, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36494107

RESUMEN

OBJECTIVES: To determine the clinical performance of light-cured calcium silicate-based cement for direct or indirect pulp capping. The research question was as follows: in teeth with deep caries lesions, does the use of resin-modified calcium silicate-containing composites improve the radiological success and prevent irreversible pulpitis and pulpal necrosis compared with other pulp-capping agents? MATERIALS AND METHODS: The following databases were screened until September 2021: PubMed, Web of Science, Scielo, Scopus, Embase, and The Cochrane Library. Randomized clinical trials reporting the clinical evaluation of a resin-modified calcium silicate material as an agent for pulp therapy were included. Meta-analysis was performed using the Rev Manager v5.4.1 software. The risk difference and 95% confidence interval of the dichotomous outcome (restoration failure or success) were calculated for comparison. RESULTS: Ten studies were considered for qualitative analysis and meta-analysis. Studies evaluating the performance of light-cured calcium silicate-based cement from 1 month to a maximum follow-up period of 36 months and comparing it with the performance of CaOH, mineral trioxide aggregate, or Biodentine were included. In the global analysis for direct pulp capping at 6-month follow-up, no statistical differences were observed between the experimental group using the light-cured calcium silicate-based cement and control group (P = .28). However, at 12-month follow-up, global analysis favored the control group (P < .001). For indirect pulp capping, at 6- and 24-month follow-ups, no statistically significant differences were observed between the experimental and control groups (P = .88; P = .21). CONCLUSIONS: Light-cured calcium silicate-based cement showed a limited clinical performance as a direct pulp capping agent, especially when evaluated in the long term. However, using it as an indirect pulp capping agent may be a reliable and easy-to-use option for restoring teeth with deep caries. CLINICAL SIGNIFICANCE: This systematic review provides evidence that supports the use of light-cured calcium silicate-based cement as an indirect pulp capping agent.


Asunto(s)
Materiales de Recubrimiento Pulpar y Pulpectomía , Humanos , Materiales de Recubrimiento Pulpar y Pulpectomía/uso terapéutico , Recubrimiento de la Pulpa Dental , Cemento de Silicato , Cementos de Ionómero Vítreo , Cementos Dentales/uso terapéutico , Resinas Compuestas
19.
Odovtos (En línea) ; 24(3)dic. 2022.
Artículo en Inglés | LILACS, SaludCR | ID: biblio-1406148

RESUMEN

Abstract Bruxism is the repetitive muscle-mandibular behavior characterized by clenching and/or grinding of the teeth, which reflects the presence of one or more underlying conditions or factors. The objective of this descriptive study was to determine the association between bruxism and stress self-perceived during the pandemic, as well as their frequency by gender and academic area. An interrogation and self-perceived stress scale PSS-14 were applied to students from the different areas of the Institute of Health Sciences (ICSa) to determine the presence or absence of stress and bruxism symptom, a Chi-square was used for the comparison between variables, considering a value of p0.005. ICSa students between 18 and 24 age perceive symptoms of bruxism and high levels of stress caused during the pandemic.


Resumen El bruxismo es el comportamiento músculo-mandibular repetitivo caracterizado por apretamiento y/o rechinamiento de los dientes, que refleja la presencia de una o varias condiciones o factores subyacentes. Se realizó un estudio descriptivo con el objetivo de determinar la asociación del nivel de estrés y síntomas de bruxismo autopercibidos durante la pandemia, así como su frecuencia por género y área académica. Se aplicó un interrogatorio y escala de estrés percibido PSS-14 a los estudiantes de las distintas áreas del Instituto de Ciencias de la Salud (ICSa) para determinar la presencia o ausencia de estrés y síntomas de bruxismo, se utilizó una Chi-cuadrada para la comparación entre variables, considerando significativo un valor de p0.0001. Los estudiantes de 18 a 24 años de edad del ICSa perciben síntomas de bruxismo y altos niveles de estrés originados durante la pandemia.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Estudiantes de Medicina , Análisis del Estrés Dental , COVID-19 , Bruxismo , México
20.
J Dent ; 127: 104313, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36208856

RESUMEN

OBJECTIVES: To evaluate the incorporation of repairing capsules containing different monomers and polymerization modulators on the self-healing efficiency of an experimental photopolymerizable resin-based composite. METHODS: Self-healing capsules containing different monomers and polymerization modulators were prepared by emulsion polymerization: TCDHEPT (TEGDMA and DHEPT), BTCDHEPT (Bis-GMA, TEGDMA, and DHEPT), and BTCBPO (Bis-GMA, TEGDMA, and BPO). The capsules were analyzed through Fourier transform infrared spectroscopy and scanning electron microscopy. The capsules were added into experimental photopolymerizable resin composites establishing the following groups: ER (Control without capsules), ER+BPO, ER+BPO+TCDHEPT, and ER+BTCBPO+BTCDHEPT. Filtek Z350 resin composite (3 M ESPE) was used as a commercial reference. The materials were tested for degree of conversion (DC), flexural strength (σf), elastic modulus (Ef), fracture toughness (virgin KIC), self-healing efficiency (healed KIC), and roughness. For statistical analysis, the significance value was established at an a = 0.05 level. RESULTS: When compared to the control material, the incorporation of repairing capsules did not affect DC, σf, and Ef. Fracture toughness was statistically similar between the experimental groups (p ≤ 0.05). Healed KIC was statistically different between the groups ER+TCDHEP and ER+BTCBPO+BTCDHEPT; the self-healing efficiency was higher for ER+TCDHEPT. Surface roughness was statistically similar among all groups. CONCLUSIONS: The use of self-healing capsules promoted repair of the material. Studies with material aging after the self-healing process are necessary to better demonstrate the effectiveness of this system. CLINICAL SIGNIFICANCE: The self-healing system seemed to be a promising technology to be used in self-repaired restorative materials, which may prevent restoration fractures.


Asunto(s)
Resinas Compuestas , Ácidos Polimetacrílicos , Bisfenol A Glicidil Metacrilato/química , Ensayo de Materiales , Resinas Compuestas/química , Ácidos Polimetacrílicos/química , Polietilenglicoles/química , Materiales Dentales/química , Cápsulas/química , Metacrilatos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...